Your advantages

  • 14 I/O's as safety inputs or redundant OSSD- outputs
  • wireless interface for safe communication, programming & diagnosis
  • IP65
  • 40mm width for aluminium safety fence systems

S14LDRB-H09-E2-I1-I1-Q1A0-Q2A0-Q3C0-Q4I0-W07
Safety Simplifier | for HOLDX R1

With the Safety Simplifier, we bring safety to where it is needed and make it easier for you to create user-friendly safety systems, such as on access doors. Simply connect your sensors, locking devices or light curtains. A complete safety solution with evaluation and diagnostics, which can be transmitted wirelessly via another Safety Simplifier or directly to your existing system in a safety-oriented manner.

 

 


Betreff: S14LDRB-H09-E2-I1-I1-Q1A0-Q2A0-Q3C0-Q4I0-W07 Safety Simplifier | for HOLDX R1

Captcha

Captcha-Feld darf nicht leer sein.


General data

Type designation
S14LDRB-H09-E2-I1-I1-Q1A0-Q2A0-Q3C0-Q4I0-W07
Item number
SP-X-89-000-47
Functional type
safety PLC with safe wireless interface, internal antenna
Button position 1
Type designation
E2
Function type
Emergency- Stop- Button
Button position 2
Type designation
I1
Function type
Illuminated Button
Button position 3
Type designation
I1
Function type
Illuminated Button
Colour
red, yellow, green, blue, white
Connection
- Position 3
Q3C- male connector M12 5-Pin
- Position 4
Q4I - female connector M12 8-Pin

Safety data

CPU
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel input
- EN ISO 13849-1: 2008
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2-channel input
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel OSSD output
- EN ISO 13849-1: 2008
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel OSSD Output
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel relais output
- EN ISO 13849-1: 2008
Category 4
- EN 62061 SIL CIL
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
Approvals
CE, TÜV

Environmental conditions

Max. storage temperature
-20°C +65 °C
Max. operating temperature
-20°C ... +65 °C

Electrical data

Technical data wireless safety
- max. amount of safe wireless channels
16
Channels
- Channel 1
2405 MHz
- Channel 2
2410 MHz
- Channel 3
2415 MHz
- Channel 4
2420 MHz
- Channel 5
2425 MHz
- Channel 6
2430 MHz
- Channel 7
2435 MHz
- Channel 8
2440 MHz
- Channel 9
2445 MHz
- Channel 11
2455 MHz
- Channel 10
2450 MHz
- Channel 12
2460 MHz
- Channel 13
2465 MHz
- Channel 14
2470 MHz
- Channel 15
2475 MHz
- Channel 16
2480 MHz
- amount of clamps
32
Supply voltage
10 - 30 V
Current consumption
110 mA with LED display
Conductor cross section
- single wire
0,08 … 0,5 mm²
- fine wire
0,08 … 0,5 mm²
- fine wired (wire sleeve without plastic collar)
0,25 mm²
stripping length
5-6 mm
configurable In-/ Outputs
14 semiconductor In-/ Outputs with help of software configurable
Amount of safe inputs
max. 14
Amount of safe semi-conductors OSSD outputs
max. 14
Amount of semi-conductors auxilliary outputs
max. 14
Amount of semi-conductors clock outputs
max. 8
Input current
HIGH 2,4 mA ... 3,8 mA LOW -2,5 mA ... 2,1 mA
Output type
PNP- Semiconductor
Output voltage
Operating voltage UB -0,5 V
Seperate output current
max. 0,6 mA (bei UB 24 V)
Total output current
max. 2 A (bei UB 24 V)
Button position 1
Type designation
E2
Function type
Emergency- Stop- Button
Switch type
2 Openers + LED
Bounce time NO
<10 ms
Bounce time NC
<10 ms
Break contact force opening
acording to EN60947-5-1 Anh-K.
Illumination
LED
mechanical lifespan
50.000 switching cycles
electrical lifespan
50.000 switching cycles
B10d- Value
250.000
Button position 2
Type designation
I1
Function type
Illuminated Button
Switch type
1 closing device + LED
Bounce time NO
<10 ms
Bounce time NC
<10 ms
Break contact force opening
according to EN60947-5-1 Anh-K
Illumination
LED
mechanical lifespan
30.000 switching cycles
electrical lifespan
30.000 switching cycles
Button position 3
Type designation
I1
Function type
Illuminated Button
Colour
red, yellow, green, blue, white
Switch type
1 closing device + LED
Bounce time NO
<10 ms
Bounce time NC
<10 ms
Break contact force opening
accordint to EN60947-5-1 Anh-K
Illumination
LED
mechanical lifespan
30.000 switching cycles
electrical lifespan
30.000 switching cycles
General data
Memory card
Installation of a memory card MEM-SP-N-88-001-93 possible
Type terminal connection
clamp terminal
- fine wired (wire sleeve with plastic collar)
0,08 … 0,5 mm²
Input voltage
HIGH 75% from UB (adjustable by software) LOW 25% from UB (adjustable by software)
Technical data inputs
Technical data safe OSSD outputs, auxilliary and test pulse outputs
Short-circuit proof
Yes

Mechanical data

Installation opening of buttons
22,5 mm
Type of housing
H09
Dimensions
Height
44 mm
Length
253 mm
Width
42 mm

Electrical drawings

Connection example 1
Connection example 1

Equipment