Your advantages

 

  • Robust design
  • Fast mounting on aluminum profiles (without the use of mounting plates)
  • Status display of the emergency stop and reset button by LED lighting
  • Fast commissioning and fast replacement with M12 plug connectors

EDI C7

Installation and commissioning

The narrow housing is particularly suitable for mounting on aluminum profiles: simply screw the retaining clip onto an aluminum profile, or attach it to the wall.

The housing is simply attached to the retaining spring and locked.Thanks to the M12 connector, the emergency stop button can be quickly put into operation or replaced. This prevents long service life.

 


Betreff: EDI C7


General data

Item number
SP-G-61-000-04
Standards
TÜV_SÜD, CE

Environmental conditions

Max. storage temperature
-25 ... +70 °C
Max. operating temperature
-25 ... +80 °C

Electrical data

Overvoltage category
II
Bounce time
< 10ms
Bounce time NC
< 10ms ms
Switch type
2 NC contacts (positively opening)(Emergency-stop)
Contact material
AgNi, gilded 5μm
Test voltage
M12 male connector, 1.5 kV
Direct opening
opener contakt, according to EN 60947-5-1, Anhang K
Direct opening path
>3 mm
Lamp socket
none, 3mm LED integrated

Mechanical data

Mounting
with backside clip

Equipment