ATM-100A5-A-ER1
ATOM Solenoid interlock, normally closed (PTU), one connection, standard wiring, escape release inside


Betreff: ATM-100A5-A-ER1 ATOM Solenoid interlock, normally closed (PTU), one connection, standard wiring, escape release inside


General data

Functional type
ATOM Solenoid interlock, normally closed (PTU), one connection, standard wiring, escape release inside
Type designation
ATM-100A5-A-ER1

Safety data

Diagnostic coverage DC
Maximum 99% with appropriate monitoring
PFHd (EN ISO 13849)
4,16 x 10⁻⁹
Construction type (acc. to ISO 14119)
Type 2
Demand rate (acc. to IEC 62061)
High
Type of coding (according to EN ISO 14119)
High
Standards
ISO 14119, EN ISO 13849, IEC 61508, EN 60947-5-2, BS EN 62061
Category (EN ISO 13849-1:2015)
up to Category 4
SIL (acc. IEC 62061)
up to SIL3 CL3

Environmental conditions

operating environment
Indoor
Contamination level
2
Max. operating temperature
-20°C bis +55°C (-4°F bis +131°F) °C
Relative humidity
50% at 70°C
Altitude
2.000 m
Vibration resistance
Tested according to GS-ET-19 and EN 60947-5-2

Electrical data

Rated operating voltage Ue
24V DC (+10%, -15%) V
Rated insulation voltage Ui
60 V
Rated impulse withstand voltage Uimp
0,5 kV
Voltage drop Ud
< 3,5 V
Rated current (on 24 VDC)
400 mA
Current consumption
min. 100 mA
Rated conditional short-circuit
100 A
Power consumption when switched off
< 0,5 mA
Overvoltage category
Type 2
Electromagnetic Compatibility (EMC)
Complies with EN 60947-5-3
Compliance with UL requirements
The unit must be operated on an energy-limited circuit. circuit. The power supply requires a 4 A fuse.
Design / Connections
1 x M12 8-pin male connector
Function type safety outputs
2 x OSSD
pin assignment with SSP accessories cable
1
White - Safety input 1
2
Brown - UB
3
Green - Safety output 1
4
Yellow - Safety output 2
5
Grey - Diagnostic output On (door open)
6
Pink - safety entrance 2
7
Blue - GND
8
Red - Solenoid On (guard locking unlocked)
Response times
Safe response time
< 200 ms
Safe input "low" to safe output "low
< 25 ms
Guard locking unlocked until safe output "low"
< 200 ms
Safety functions
Safety function 1
Secure inputs on
Safety function 2
Protective device closed
Safety function 3
Safety guard kept closed
Safe state 1
1 OSSD output off
Safe state 2
Protective device closed

Mechanical data

Housing material
Passivated and painted zinc alloy to BSEN12844 ZA3 and stainless steel acc. to BS3146-2:1975 (ANC4B)
Mechanical service life
1.000.000 switching cycles
Locking force Fmax
5.000 N
Locking force FZh
6000 N
Maximum locking force F1max
12000 N
Minimally actuation radius
150 mm (see figure 5)
Maximum actuation frequenzy
720 switching cycles per hour

Electrical drawings

Pin assignment 1
Pin assignment 1

Drawings

Dimensions
Dimensions

Equipment