S16LDRB-H10-Q1A-Q2A-Q3A-Q4A

Your advantages

  • 14 I/O's as safety Inputs or redundant OSSD- Outputs
  • wireless Interface for safe communication, programming & diagnosis
  • IP65
  • 40mm width for aluminium safety fence systems

S14LDRX-H10-Q1A0-Q2A0-Q3A0-Q4A0
Safety Simplifier | S14 control cabinet unit with external antenna connection

With the Safety Simplifier we take safety where it is needed and we provide safety where it is needed with the Safety Simplifier and make it easier for you to develop user-friendly safety systems, such as on access doors. Simply connect up your sensors, locking systems or light curtains. Select the required push button and/or emergency stop button and you have a complete safety solution with analysis and diagnosis functions. his data is wirelessly transmitted via another Safety Simplifier or directly transmitted to your existing system in a fail-safe manner.

 


Betreff: S14LDRX-H10-Q1A0-Q2A0-Q3A0-Q4A0 Safety Simplifier | S14 control cabinet unit with external antenna connection


General data

Type designation
S14LDRX-H10-Q1A0-Q2A0-Q3A0-Q4A0
Item number
SP-X-89-007-59
Functional type
Safety PLC with safe wireless interface, internal antenna

Safety data

CPU
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel input
- EN ISO 13849-1: 2008
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2-channel input
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel OSSD output
- EN ISO 13849-1: 2008
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel OSSD Output
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel relais output
- EN ISO 13849-1: 2008
Category 4
- EN 62061 SIL CIL
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
Approvals
CE, TÜV

Environmental conditions

Max. storage temperature
-20 °C ... +65 °C
Max. operating temperature
-20 °C ... +65 °C

Electrical data

Technical data wireless safety
- max. amount of safe wireless channels
16
Channels
- Channel 1
2405 MHz
- Channel 2
2410 MHz
- Channel 3
2415 MHz
- Channel 4
2420 MHz
- Channel 5
2425 MHz
- Channel 6
2430 MHz
- Channel 7
2435 MHz
- Channel 8
2440 MHz
- Channel 9
2445 MHz
- Channel 11
2455 MHz
- Channel 10
2450 MHz
- Channel 12
2460 MHz
- Channel 13
2465 MHz
- Channel 14
2470 MHz
- Channel 15
2475 MHz
- Channel 16
2480 MHz
- amount of clamps
32
Supply voltage
10 - 30 V
Current consumption
110 mA with LED display
Conductor cross section
- single wire
0,08 … 0,5 mm²
- fine wire
0,08 … 0,5 mm²
- fine wired (wire sleeve without plastic collar)
0,25 mm²
stripping length
5-6 mm
configurable In-/ Outputs
14 semiconductor In-/ Outputs with help of software configurable
Amount of safe inputs
max. 14
Amount of safe semi-conductors OSSD outputs
max. 14
Amount of semi-conductors auxilliary outputs
max. 14
Amount of semi-conductors clock outputs
max. 14
Input current
HIGH 2,4 mA ... 3,8 mA LOW -2,5 mA ... 2,1 mA
Output type
PNP- semiconductor
Output voltage
Operating voltage UB -0,5 V
Seperate output current
max. 600 mA (with UB 24 V)
Total output current
max. 2 A (with UB 24 V)
General data
Memory card
Installation of a memory card MEM-SP-N-88-001-93 possible
Programming connection
Micro USB, Wireless Interface
Type terminal connection
clamp terminals
- fine wired (wire sleeve with plastic collar)
0,08 … 0,5 mm²
Input voltage
HIGH 75% of UB (adaptable with software) LOW 25% of UB (adaptable with Software)
Technical data safe OSSD outputs, auxilliary and test pulse outputs
Short-circuit proof
Yes

Mechanical data

Installation opening of buttons
22,5 mm
Type of housing
H10
Dimensions
Height
44 mm
Length
253 mm
Width
42 mm

Electrical drawings

Connection example 1
Connection example 1

Equipment