MOSAIC MO2C

Your advantages

  • 2 OSSD output pairs
  • 2 programmable status outputs
  • 2 inputs for feedback circuit
  • Width 22.5mm
  • Modular expansion of the system
  • Free Mosaic Safety Designer software
  • Easy and quick programming
  • Online mode

MOSAIC MO2C

Output expansion Units

2 inputs for Start/Stop interlock and device monitoring (EDM), 2 OSSD pairs and 2 programmable digital signal outputs

Clamp contacts 



Betreff: MOSAIC MO2C


Safety data

PFHd (EN ISO 13849)
4.09E-9
SIL (acc. IEC 62061)
SIL 3 - SILCL 3 according to IEC 61508 - IEC 62061 / PL e - Cat. 4 according to ISO 13849-1
MTTFd (ISO 13849-1) years
1016,28
CCF (ISO 13849-1)
80%

Environmental conditions

Max. storage temperature
-20 ... +85 °C
Max. operating temperature
-10 ... +55 °C

Electrical data

LED lighting
Input/output status and fault diagnostics
MSC plug connector supplied
Yes
Connection to MSC bus
Yes

Mechanical data

Dimensions
Height
99 mm
Width
22,5 mm
Length
114 mm
Mounting
Rail fastening according to EN 50022-35 standard

Equipment