S00RB-H00-Q1A0-Q2A0-Q3C0-Q4A0

Your advantages

  • Wireless Interface for safe communication, programming & diagnosis
  • IP65
  • 40mm width for aluminium safety fences systems

S00RB-H00-Q1A0-Q2A0-Q3C0-Q4A0
Safety Simplifier | Repeater with external antenna


Betreff: S00RB-H00-Q1A0-Q2A0-Q3C0-Q4A0 Safety Simplifier | Repeater with external antenna


General data

Type designation
S00RB-H00-Q1A0-Q2A0-Q3C0-Q4A0
Item number
SP-X-89-002-13
Functional type
Repeater with wireless Interface, internal antenna

Safety data

CPU
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel input
- EN ISO 13849-1: 2008
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2-channel input
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel OSSD output
- EN ISO 13849-1: 2008
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel OSSD Output
- EN ISO 13849-1: 2008
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel relais output
- EN ISO 13849-1: 2008
Category 4
- EN 62061 SIL CIL
SIL CL 3
- EN 62061 PFHD [1/h]
- EN ISO 13849-1: 2008 TM [Year]
20
Approvals
CE, TÜV

Environmental conditions

Max. storage temperature
-20 °C...+65 °C °C
Max. operating temperature
-20 °C...+65 °C °C

Electrical data

- max. amount of safe wireless channels
16
- Channel 1
2405 MHz
- Channel 2
2410 MHz
- Channel 3
2415 MHz
- Channel 4
2420 MHz
- Channel 5
2425 MHz
- Channel 6
2430 MHz
- Channel 7
2435 MHz
- Channel 8
2440 MHz
- Channel 9
2445 MHz
- Channel 11
2455 MHz
- Channel 10
2450 MHz
- Channel 12
2460 MHz
- Channel 13
2465 MHz
- Channel 14
2470 MHz
- Channel 15
2475 MHz
- Channel 16
2480 MHz
- amount of clamps
32
Supply voltage
10 - 30 V
Current consumption
110 mA with LED display
- single wire
0,08...0,5 mm²
- fine wire
0,08...0,5 mm²
- fine wired (wire sleeve without plastic collar)
0,25 mm²
Input current
HIGH 2,4 mA ... 3,8 mA LOW -2,5 mA ... 2,1 mA
Seperate output current
max. 600 mA (with UB 24 V)
General data
Programming connection
Micro USB, Wireless Interface
Type terminal connection
Spring clamp
- fine wired (wire sleeve with plastic collar)
0,08...0,5 mm²
Input voltage
HIGH 75% from UB (adjustable by software) LOW 25% from UB (adjustable by software)
Technical data inputs

Mechanical data

Installation opening of buttons
22,5 mm
Type of housing
H08
Dimensions
Height
44 mm
Length
253 mm
Width
42 mm

Electrical drawings

Connection example 1
Connection example 1

Equipment