S14LDRB-H0A-E2-I1-I1-K8-Q1A-Q2A-Q3C-Q4A-W05

Your advantages

  • 14 I/O's as safety inputs or redundant OSSD- outputs
  • wireless interface for safe communication, programming & diagnosis
  • IP65
  • 40mm width for aluminium safety fence systems

S16LDRB-H0A-E2-I1-I1-K4-Q1A0-Q2A0-Q3C0-Q4A0-W67
Safety Simplifier | for safety relais

With the Safety Simplifier, we bring safety to where it is needed and make it easier for you to create user-friendly safety systems, such as on access doors. Simply connect your sensors, guard locking devices or light curtains. A complete safety solution with evaluation and diagnostics, which can be transmitted wirelessly via another Safety Simplifier or directly to your existing system in a safety-oriented manner.


Betreff: S16LDRB-H0A-E2-I1-I1-K4-Q1A0-Q2A0-Q3C0-Q4A0-W67 Safety Simplifier | for safety relais


General data

Type designation
S16LDRB-H0A-E2-I1-I1-K4-Q1A0-Q2A0-Q3C0-Q4A0-W67
Item number
SP-X-89-100-42
Functional type
safety PLC with safe wireless interface, internal antenna
Button position 1
Type designation
E2
Function type
Emergency- Stop- Button
Button position 2
Type designation
I1
Function type
Illuminated Button
Button position 3
Type designation
I1
Function type
Illuminated Button
Button position 4
Type designation
K4
Function type
Key switch resting, 2 Positions, 2 x NO
Colour
red, yellow, green, blue, white
Connection
- Position 1
Q1A0 - Connection bottom left with cover
- Position 2
Q2A0 - Connection top left with cover
- Position 3
Q3C0 - male connector M12 5-Pin
- Position 4
Q4A0 - Connection top right with cover