Your advantages

  • Width of just 22,5mm
  • Removable coded connection blocks
  • One safety relay for each input connection:
    • Single channel
    • Two channel
    • Feedback circuit
    • Test input
  • High current-carrying capacity of up to 6A
  • LED diagnosis

T series
Time delay safety relay 1 safety function


Betreff: T series Time delay safety relay 1 safety function


General data

Type designation
T series
Item number
SP-S-00-002-01
Functional type
Safety relay with integrated time delay
Service life TM (EN ISO 13849-1)
20 Years

Safety data

PFHd (EN ISO 13849)
\"3 x 10–8 contacts 13/14, 23/24 2 x 10–7 contacts 37/38\"
Category (EN ISO 13849-1:2015)
cat. 4
SIL (acc. IEC 62061)
SILCL3
Approvals
TÜV_SÜD, CE

Environmental conditions

Max. storage temperature
-25 ... +75 °C
Max. operating temperature
-25 ... +55 °C

Electrical data

Rated operating voltage Ue
AC 300 V
Rated impulse withstand voltage Uimp
4 kV
Overvoltage category
II
Conditional short-circuit current
1000 A
Utilisation category
\"AC-15 Ue 230 V AC, Ie 3 A (360 Sch/h) DC-13 Ue 24 V DC, Ie 2 A (360 Sch/h)\"
B10d-value
\"400 × 103 switching cycles (at maximum load)\"

Mechanical data

Stranded wire with end ferrules
\"1 x 0,25 mm² to 2,5 mm² 2 x 0,25 mm² to 0,5 mm²\"
Mechanical service life
5 x 10^6 switching cycles switching cycles
Maximum tightening torque
0,6 Nm