Betreff:


General data

Item number
ITM-00429781
Type designation
IBL2H-1-1-CLSS-MP1
Functional type
IBL - Blocking latch for hinged doors with safety key - stop left

Environmental conditions

Max. operating temperature
-25°C to +80°C *Note: When operating below the freezing point (0 °C), it must be ensured for proper operation that no ice can form on or in the device, as otherwise mechanical parts can become blocked or jammed. °C
Environment Type
Indoor and outdoor
Vibration resistance
Tested according to IEC 60068-2-6 and IEC 60068-2-27

Mechanical data

Housing material
316 Stainless Steel and Stainless Steel to BS3146-2:1975 (ANC4B)
Mechanical service life
1,000,000 operations switching cycles
Maximum door thickness
70mm for ≥600mm door width - Note: Any gaps in the door frame when closed must not exceed the limits specified in BS EN ISO 13857.

Drawings

Dimensions
Dimensions